Calibration: Volume

Calibration: Volume

 QAS scope of calibration capability TRACEABILITY to International Standards (SI UNITS) is offered through Kenya Bureau of Standards (KEBS).

LAB

SCOPE

CAPABILITY RANGE

STANDARDS

VOLUME & FLOW LAB

MIXING TANKS,

STORAGE TANKS,

SILO TANKS,

SMALL VOLUMES(PIPETTES)

LEVEL INDICATORS TRANSMITTERS

100-1,000,000 LITRES,

 

10µl TO 100 ml

 

1,000,000 LITRES

PROVER TANKS:

20 LITRES,

100 LITRES,

1000 LITRES,

ANALYTICAL BALANCE,

ULTRASONIC FLOW METER,

MECHANICAL FLOW METER,

PROCESS METER,

THEODOLITE MACHINE FOR DRY METHOD,

UT THICKNESS GAUGE


Recomended calibration schedule:

Volume and Flow Calibration Services

NO

STANDARD/ EQUIPMENT

MAX. INTERVAL OF TIME BEFORE NEXT CALIBRATION

1

Tanks not more than 20 litres capacity

1 year

2

Tanks larger than 20 but less than 200 litres

1 year

3

Tanks larger than 200 but less than 500 litres

1 year

4

Tanks larger than 500 but less than 1000 litres exclusive

1 year

5

Tanks from 1001 to 3000 litres

1 year

6

Tanks from 3001 to 5000 litres

1 year

7

Tanks from 5001 to 7000 litres

1 year

8

Tanks from 7001 to 9000 litres

1 year

9

Tanks from 9001to 11000 litres

2 year

10

Tanks from 11001to 13000 litres

2 year

11

Tanks from 13001to 15000 litres

2 year

12

Tanks from 15001to 17000 litres

2 year

13

Tanks from 17001 to 19000 litres

2 year

14

Tanks from 19001 to 21000 litres

2 year

15

Tanks from 21001 to 23000 litres

2 year

16

Tanks from 23001 to 25000 litres

5 year

17

Tanks from 25001 to 27000 litres

5 year

18

Tanks from 27001 to 29000 litres

5 year

19

Tanks from 29001 to31000 litres

5 year

20

Tanks from 31001 to 35000 litres

5 year

21

Tanks from 35001 to 50000 litres

5 year

22

Tanks from 50001 to 60000 litres

5 year

23

Tanks from 60001 to 70000 litres

5 year

24

Tanks from 70001to 80000 litres

5 year

25

Tanks from 80001 to 90000 litres

5 year

26

Tanks from 90001 to 100000

5 year

27

Tanks from 100,001 to 120,000 litres

5 year

Prover Tanks

NO

STANDARD/ EQUIPMENT

MAX. INTERVAL OF TIME BEFORE NEXT CALIBRATION

28

Prover tanks 5 liters

1 year

29

Prover tanks 10 liters

1 year

30

Prover tanks 20 liters

1 year

31

Prover tanks 50 liters

1 year

32

Prover tanks 100 liters

1 year

33

Prover tanks 200 liters

1 year

34

Prover tanks 250 liters

1 year

35

Prover tanks 500 liters

1 year

36

Prover tanks 1000 liters

1 year

37

Prover tanks 2500 liters

1 year

38

Prover tanks 5000 liters

1 year

Flow Meter

NO

STANDARD/ EQUIPMENT

MAX. INTERVAL OF TIME BEFORE NEXT CALIBRATION

39

Flow meter upto 1”

1 year

40

Flow meter 2”

1 year

41

Flow meter 3”

1 year

42

Flow meter 4”

1 year

43

Flow meter 5”

1 year

44

Flow meter 6”

1 year

45

Flow meter above 6”

1 year

Please note that we prefer to undertake our testing/calibration assignments on site in order to minimize disruptions to our clients’ operations .

 

©2021 Quality Assurance Systems Limited. All Rights Reserved.

Please publish modules in offcanvas position.